5 - 48 DS36X8 Digital Scanner Product Reference Guide
Page State Timeout
Parameter # 1365 (F8h 05h 55h)
Page timeout is programmable in 1 second increments from 1 to 99 seconds. The default timeout is 30 seconds.
To set a page timeout:
1. Scan the Page Timeout barcode below.
2. Scan two numeric barcodes from Appendix H, Numeric Bar Codes that correspond to the desired timeout
duration. Enter a leading zero for single digit numbers (for example, for a 5 second page timeout, scan the
0 barcode and then the 5 barcode).
To correct an error or change the selection, scan
Cancel on page H-2.
Bluetooth Classic Bluetooth and/or Low Energy (Cradle Parameter
Only/ Cradle Host Only)
Parameter # 1355 (F8h 05h 8Bh)
Set up cradle to accept both Bluetooth Classic and Low Energy connections or Low Energy Only connections.
NOTE Page State Timeout only applies to Page State Mode.
Page Timeout
NOTE All Classic Bluetooth connections must be terminated before the setting can change to Low
Energy Only.
* Classic Bluetooth and Low Energy
(0)
Low Energy Only
(1)