User Manual

12 - 2 DS2208 Digital Scanner Product Reference Guide
Scanning Sequence Examples
In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the
UPC-A check digit, scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check Digit
on page 12-18. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter
entry.
Other parameters, such as Set Lengths for D 2 of 5, require scanning several bar codes. See the parameter
descriptions for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Symbology Parameter Defaults
Table 12-1 lists defaults for all symbology parameters. Change these values in one of two ways:
Scan the appropriate bar codes in this chapter. The new value replaces the standard default value in
memory. To recall the default parameter values, see Default Parameters on page 5-5.
Configure the scanner using the 123Scan
2
configuration program. See Chapter 12, Symbologies.
NOTE See Appendix A, Standard Default Parameters for all user preference, host, symbology, and
miscellaneous default parameters.
Table 12-1 Symbology Parameter Defaults
Parameter
Parameter
Number
1
SSI Number
2
Default
Page
Number
Enable/Disable All Code Types
12-8
1D Symbologies
UPC/EAN/JAN
UPC-A 1 01h Enable 12-8
UPC-E 2 02h Enable 12-9
UPC-E1 12 0Ch Disable 12-9
EAN-8/JAN 8 4 04h Enable 12-10
EAN-13/JAN 13 3 03h Enable 12-10
Bookland EAN 83 53h Disable 12-11
Bookland ISBN Format 576 F1h 40h ISBN-10 12-12
ISSN EAN 617 F1h 69h Disable 12-12
1. Parameter number decimal values are used for programming via RSM commands.