Instructions

1 - 28 CS3000 Series Scanner Product Reference Guide
ScanParam Variable Any scan engine parameter. Multiple
entries are allowed. Sent after reset or
when engine is powered.
For example:
ScanParam=0xf0,0x00,0x01
ScanParam=0xee,0x01
ScanParam=0x38,0x00
<none>
CodeID Enabled
Disabled
Enable or disable saving CodeID in the
scanned bar codes file. See
Code Type
IDs on page B-1
.
Enabled
Maximum Bar
Code Length
Integer Maximum length of a bar code that can be
scanned and transmitted to host.
60
Table 1-1
Config.ini File Content (Continued)
Parameter Values Description Default