Reference Guide

Table Of Contents
Programming Reference
476
Code 93 0 No options specified at this time. Always transmit 0.
Example: A Code 93 barcode 012345678905 is transmitted as ]G0012345678905
MSI 0 Check digits are sent.
1 No check digit is sent.
Example: An MSI barcode 4123, with a single check digit checked, is transmitted as
]M14123
D 2 of 5 0 No options specified at this time. Always transmit 0.
Example: A D 2 of 5 barcode 4123, is transmitted as ]S04123
UPC/EAN 0 Standard data packet in full EAN format, i.e. 13 digits for UPC-A,
UPC-E, and EAN-13 (not including supplemental data).
1 Two digit supplemental data only.
2 Five digit supplemental data only.
3 Combined data packet comprising 13 digits from EAN-13, UPC-A
or UPC-E symbol and 2 or 5 digits from supplemental symbol.
4 EAN-8 data packet.
Example: A UPC-A barcode 012345678905 is transmitted as ]E00012345678905
Bookland EAN 0 No options specified at this time. Always transmit 0.
Example: A Bookland EAN barcode 123456789X is transmitted as ]X0123456789X
ISSN EAN 0 No options specified at this time. Always transmit 0.
Example: An ISSN EAN barcode 123456789X is transmitted as ]X0123456789X
Code 11 0 Single check digit
1 Two check digits
3 Check characters validated but not transmitted.
GS1 DataBar
Family
No option specified at this time. Always transmit 0. GS1 DataBar
Omnidirectional and GS1 DataBar Limited transmit with an
Application Identifier “01”.
Note: In GS1-128 emulation mode, GS1 DataBar is transmitted
using Code 128 rules (i.e., ]C1).
Example: A GS1 DataBar Omnidirectional
barcode 0110012345678902 is transmitted
as ]e00110012345678902.
Table 26 Modifier Characters (Continued)
Code Type Option Value Option
guide-user-color-8.5x11.book Page 476 Monday, June 1, 2020 5:43 PM