pg. 14-191
continued
rd.position.program
Type getvar; setvar
Description This command sets the read/write position of the RFID transponder in vertical (Y axis) dot
rows from the top of the label. Set to 0 (no movement) if the transponder is already in the effective area
without moving the media.
Important • If a label format species a value for this parameter, this value will be used for the programming position for all
subsequent labels until a new position is specied or until the printer is turned o (O) and then back on (I).
getvar results Description
This command instructs the printer to respond with the current
programming position
Example
Syntax ! U1 getvar “rfid.position.program
Result Printer returns the current programming position
setvar
Description
This command instructs the printer to set the programming
position
Syntax ! U1 setvar “rfid.position.program” “value”
setvar choices
“value” can equal “0” to label length
Default value “(label length minus 1 mm [1/16 in.])”
Example
Syntax ! U1 setvar “rfid.position.program” “15”
Result Programming position is set to “15
This setvar example shows the programming position being set at 15 dot rows from the top of the label.