User Manual
RMAN-Cameo rev. C • 2- 10 •
CPU BOARD, CAMEO 2- AN16793-013 & -014
Removing the CPU Board
1. Remove the media and battery. Refer to the
Cameo Portable Printers User’s
Manual
.
2. Remove the Top Cover. Refer to “Top Cover - Cameo 2 & 3.”
3. Remove the 4 screws from the CPU Board.
4. Unplug all cables from the CPU Board, and remove the CPU Board.
5. Unplug the SRRF module from the CPU Board.
Installing the CPU Board
1. Install the SRRF Module (PCC digit 7 = 2, 3, 4, 6, 8, 9, B)
1a. Plug the SRRF Assembly into the bottom of the CPU Board. The 8-pin
connector on the SRRF Assembly plugs into the connector on the bottom of the
CPU Board marked RF1.
1b. Install the Antenna (PCC digit 7 = 9 or B) (See illustration on next page)
Attach the Antenna lead to the Radio Module. If necessary, secure it to the lower
chassis with Super-Bond tape. Refer to the appropriate SRRF section for further
information on the SRRF options.
The Tear Bar on the Printer Assembly has sharp edges. Use caution
when performing operations near the printer.
You must use an ESD strap and work at a properly grounded
workstation (antistatic mat or tray). All electronic components must
be placed on an ESD protective tray. If stored, any electronic
components must be placed in antistatic bags.
PCB Assy.
SRRF Assy.