Datasheet

44895L Rev. 3 3/15/04 S400/S600 Maintenance Manual Page 4-17
3UHYHQWLYHDQG&RUUHFWLYH0DLQWHQDQFH 6HFWLRQ
Table 4-2. Self Test and Calibration Reference Table
Operator Description
Pause
Key
Feed
Key
Cancel
Key
Mode
Key
Cancel Key Self Test – Produces a printer
configuration label printout
X
Pause Key Self Test – Produces test
printouts for adjustments (15 or 50 labels @
2 or 6 ips)
X
Feed Key Self Test – Produces test
printouts to determine the best darkness
setting
X
Mode Key Self Test – Produces a
communications diagnostic mode printout
X
Factory Default Reset – Resets printer
configuration to factory default values
XX
Communication Parameter Default Reset
– Resets printer communication parameters
to 9600 baud, 8 bit work length, no parity,
and
1 stop bit.
XX X
Manual Calibration – Printer determines
the media type, label length, media, and
ribbon sensor settings, and printing method.
XXX
Pause and Cancel Key Self Test
Serialized test printouts verify proper printer
operation (500 maximum)
XX
Ribbon Parameter Calibration – Sets
ribbon parameters to factory default values.
XXX
Feed and Cancel Key Self Test –
Preprogrammed label test formats for major
overhauls
XX
Note • This test is performed only when sensor assemblies are replaced or if a manual
calibration fails. A manual calibration procedure must be performed after the ribbon
parameter calibration.