Datasheet
44895L Rev. 3 3/15/04 S400/S600 Maintenance Manual Page 4-17
3UHYHQWLYHDQG&RUUHFWLYH0DLQWHQDQFH 6HFWLRQ
Table 4-2. Self Test and Calibration Reference Table
Operator Description
Pause
Key
Feed
Key
Cancel
Key
Mode
Key
Cancel Key Self Test – Produces a printer
configuration label printout
X
Pause Key Self Test – Produces test
printouts for adjustments (15 or 50 labels @
2 or 6 ips)
X
Feed Key Self Test – Produces test
printouts to determine the best darkness
setting
X
Mode Key Self Test – Produces a
communications diagnostic mode printout
X
Factory Default Reset – Resets printer
configuration to factory default values
XX
Communication Parameter Default Reset
– Resets printer communication parameters
to 9600 baud, 8 bit work length, no parity,
and
1 stop bit.
XX X
Manual Calibration – Printer determines
the media type, label length, media, and
ribbon sensor settings, and printing method.
XXX
Pause and Cancel Key Self Test –
Serialized test printouts verify proper printer
operation (500 maximum)
XX
Ribbon Parameter Calibration – Sets
ribbon parameters to factory default values.
XXX
Feed and Cancel Key Self Test –
Preprogrammed label test formats for major
overhauls
XX
Note • This test is performed only when sensor assemblies are replaced or if a manual
calibration fails. A manual calibration procedure must be performed after the ribbon