Datasheet

44895L Rev. 3 3/15/04 S400/S600 Maintenance Manual Page 4-3
3UHYHQWLYHDQG&RUUHFWLYH0DLQWHQDQFH 6HFWLRQ
(TXLSPHQW6DIHW\7LSV&RQWLQXHG
o To ensure optimum printhead life, observe proper electrostatic safety
precautions (for example; ESD, Electrostatic Service Device, wrist straps)
when removing, handling, and replacing the printhead.
o Zebra recommends using solvent containing 90% isopropyl alcohol and 10%
distilled water for cleaning:
Printheads
Platen Rollers
Peel-Off Roller
•Media Path
Peel/Tear Bar
Spindles
o Ribbons used in the printers must be as wide as or wider than the media. If the
ribbon is narrower than the media, areas of the printhead will be unprotected
and subject to premature wear.
o To ensure the printer has proper ventilation and cooling, do not place any
padding or cushioning material under the unit because this restricts air flow.
o Install Zebra printers on a solid, level surface of sufficient size and strength to
accommodate the physical dimensions and weight of the unit. The area
enclosure in which the printer will operate must meet the environmental
conditions specified in the maintenance manual or User’s Guide. Electrical
power must be available and in close proximity to the printer.