44895L Rev. 3 3/12/04 S400/S600 Maintenance Manual Page 2-21
2SHUDWLRQV2YHUYLHZ 6HFWLRQ
&DOLEUDWLRQ
$XWR&DOLEUDWLRQ
Auto calibration occurs when the printer is turned On (l) or when the printhead is opened
and closed (with the printer turned on). During the procedure, the printer automatically
determines the media type, label length, media and ribbon sensor settings, and printing
method (direct thermal or thermal transfer). The procedure is set at the factory but may be
changed via ZPL II command.
1. Load the media and ribbon.
2. Turn the printer On (l).
3. Several blank labels feed, completing the auto calibration procedure.
Note • If the printer fails to auto calibrate when you are using preprinted labels or
preprinted liner, or if the printer does not auto calibrate at all, refer to
“Manual Calibration” on page 2-22.