44895L Rev. 3 3/12/04 S400/S600 Maintenance Manual Page 2-15
2SHUDWLRQV2YHUYLHZ 6HFWLRQ
3ULQWHU6HOI7HVW5HVHW'HIDXOW4XLFN5HIHUHQFH&KDUW
Table 2-1 lists the self tests and default resets that can be accessed by pressing and
holding a front panel key or keys and turning power on. The “X” in the four columns on the
right indicates which key or keys are pressed.
The indicates that the self test is one that can be performed by the operator or
maintenance personnel. These tests produce sample labels and provide specific
information that helps the operator or maintenance personnel determine operating
conditions for the printer. Self tests without the are for repair and maintenance of the
printer and should be performed only by maintenance personnel.
Detailed information on the operator self tests immediately follows this chart. Detailed
information on maintenance personnel-only self tests are found in Preventive and
Corrective Maintenance” on page 4-1 along with extended diagnostics.
NoteThe printer data cable must be removed from the printer (except for the Mode
Key Self Test) prior to running the self tests.
Table 2-1. Self Test and Calibration Quick Reference Chart
Operator Description Pause Feed Cancel Mode
3
Cancel Key Self Test Produces a printer
configuration label printout
X
3
Pause Key Self Test — Produces test
printouts for adjustments (15 or 50 labels
@ 2 or 6 ips)
X
3
Feed Key Self Test — Produces test
printouts to determine the best darkness
setting
X
3
Mode Key Self Test — Produces a
Communications Diagnostic Mode printout
X
3
Factory Default Reset — Resets printer
configuration to factory default values
X X
3
Communication Parameter Default Reset
— Resets printer communication
parameters to 9600 baud, 8 bit work length,
no parity, and 1 stop bit
X X X
3
Manual Calibration — Determines media
type, label length, media and ribbon sensor
settings, and printing method
X X X
Pause and Cancel Key Self Test
Serialized test printouts that verify proper
printer operation (500 maximum)
X X
Ribbon Parameter Calibration — Sets
ribbon parameters to factory default values.
X X X
Feed and Cancel Key Self Test
Preprograms label test formats for major
overhauls
XX
Note • This test is performed only when sensor assemblies are replaced or when a
manual calibration fails. A Manual Calibration must be performed after the Ribbon
Parameter Calibration.