Specifications

Media Tracking Adjustments
Rewind Mode
If the media walks from side to side, or if it tears or wrinkles against the
Media Rewind Tracking Plate, it will be necessary to adjust the Rewind Plate
Assembly. Refer to Figures 5.10 and 5.11.
1. Remove the Rewind Plate Assembly and loosen the 5/16” Hex nuts
attaching the Hook Plate to the Rewind Plate. Moving the outer end of the
Hook Plate up will force the media towards the Rewind Tracking Plate
while moving this end down will move the media away from the Tracking
Plate. (The opposite effect will occur if the same adjustments are performed
on the inner end of the Hook Plate.)
2. Tighten the Hex nuts, reinstall the Rewind Plate Assembly, and print several
test labels. If problems persist, readjust the Hook Plate.
3. (105S and 105SeOnly)If the media cannot be made to track correctly with
the previous adjustment, check the distance from the outside of the Tracking
Plate to the Main Frame. This dimension is set at the factory and should be
0.530" (13.5 mm) to 0.570" (14.5 mm). If the distance needs to be reset,
refer to Figure 5.11 and proceed to step 4 below.
4. (105S and 105Se Only) Use a 1/16" Hex Allen Wrench to loosen the two
set screws in the Collar (located inside the Rewind Spindle Assembly). The
screws are accessible through a single hole in the Spindle Assembly, as
shown in Figure 5.11. Reposition the Spindle Assembly closer to or farther
from the Main Frame as required, and retighten the two set screws in the
collar.
5. Repeat steps 1 and 2 until the required results are achieved.
REWIND PLATE
HOOK PLATE
HOOK PLATE
OUTER END
HEX NUTS
Corrective Maintenance
S
-Series Maintenance Manual: Volume 1
Page 5-20 38452L Rev. 3