Specifications

Adjusting the Position of the Top of the Label
1. Press the MODE key twice, then press and hold the MODE key for about
five seconds, until the lights change. PAUSE, DARKEN, and CALIBRATE
lights turn on.
2. Press the UP or DOWN key to adjust the current setting.
3. Press the MODE key twice. The MODE lights will flash on and off to
indicate that the settings have been saved in memory.
4. Press PAUSE to exit the PAUSE mode; the PAUSE light turns off.
Adjusting the Media Sensor Positions
This sensor is not used if Black Mark sensing is selected.
NOTE: If you’re using continuous media, do not perform this adjustment.
Leave the media sensor at the factory-set position.
Non-continuous media has a notch or opening between each label. To monitor
label movement you need to align the media sensor with this notch or opening.
The media sensor consists of two parts that must be properly aligned with the
notch or edge of the label. The factory-set position should be sufficient for most
applications. If not, perform the appropriate adjustments.
Adjusting the Upper Media Sensor
To adjust for the inside half of the media:
1. Remove the ribbon. Locate the upper media sensor (Figure 2.9-A).
2. Loosen, but do not remove, the Phillips head screw.
3. Slide the upper sensor along the slot to any position along the web, except
where the rounded corners of the label are detected. When using tag stock,
position the upper sensor directly over the hole or notch.
4. Tighten the screw.
S
-Series Maintenance Manual: Volume 1 Getting Ready to Print
38452L Rev. 3 Page 2-9