46 980428-123 Rev. 1 Prelim.
4. Pull the label taken sensor PCBA out of the
sensor gate’s sensor shroud. Gently pull the
shroud body away from the gate to get the
PCBA past the snap locks on the inside of
the shroud.
5. Slide the cable out of the shroud.
Installation
1. Reverse the process.