User's Manual
Configuration
Control Panel Parameters
96
13383L-004 Rev. A XiIIIPlus/R110Xi/R170Xi User Guide 9/6/07
Select Resynch Mode
This parameter determines how the printer reacts if the label 
synchronization is lost and the label top is not where expected.
Default: FEED MODE
Selections: FEED MODE, ERROR MODE
• FEED MODE—If the label top is not where expected, the printer feeds 
a blank label to find the label top position.
• ERROR MODE—If the label top is not where expected, the printer 
stops, enters Pause mode, displays the message 
Error Condition 
Feed Label
, flashes the ERROR light, and asserts the Service 
Required signal (pin 10 on the Applicator Interface Connector).
To resynch the media to the top of the label in Error mode, press 
PAUSE to exit Pause mode. The ERROR light stops flashing, and the 
Service Required signal is deactivated. The action of the printer is 
determined by the 
Head Close configuration selection (see Select 
Head Close Option on page 91).
To change the value shown:
1. Press the left or right oval to toggle between the options.
These parameters are automatically set during the calibration procedure 
and should be changed only by a qualified service technician. Refer to the 
ZPL II Programming Guide for information on these parameters.
To skip these parameters:
1. Press NEXT/SAVE repeatedly.
Table 10 • Printer Parameters (Sheet 25 of 27)
Parameter
Action/Explanation
RESYNCH MODE
- FEED MODE +
WEB S. 073
-   +
MEDIA S. 075
-   +
RIBBON S. 071
-   +
TAKE LABEL
-   +
MARK S. 000
-   +
MARK MED S. 000
-   +
MEDIA LED 082
-   +
RIBBON LED 008
-   +
MARK LED 005
-   +