Specifications

Administrator Console 4 - 29
Firmware Version/Update
The Firmware Version/Update window displays the current firmware version and allows upgrading to new firmware.
From the
Administrator Console, click Firmware.
The firmware version information window displays:
Hardware - The current hardware version.
Reader Application - The current reader application software version.
OS - The current operating system build version.
MAC - The current MAC (radio) firmware version.
Monitor - The current monitor utility version.
Radio API - The current radio API version.
The reader supports two different methods of updating the firmware:
FTP / FTPS Server
File Upload on page 4-31
Select either the FTP / FTPS Server radio button or the Firmware Upload radio button to select the appropriate
firmware update method.
Either method shows the current firmware update progress on the same window. After upgrading the necessary
partitions the reader reboots with a message
Reboot to indicate that the firmware upgrade completed.
FTP / FTPS Server
FTP / FTPS Server - Identifies the location of the current software updates, the response file that contains the
names of the partitions to update, and the partitions. Use an IP address or domain name in this link,
beginning with ftp:// (or ftps://).
User Name - Required for appropriate access to the FTP / FTPS server.
User Password - Password for the above FTP / FTPS User Name.
Update All Partitions - Check to force the update of all reader partitions. This increases firmware update time.
Start Update - Click to start the update. The reader application shuts down and the files listed in the
Response.txt file are downloaded, validated, and programmed into flash. The reader reboots. If files are not
downloaded or are corrupted during the download, they are not programmed into flash and the old partitions
remain. The PWR LED blinks red during the upgrade. If the upgrade fails, the STAT LED turns red. If the
upgrade succeeds, the reader resets and the PWR LED eventually turns solid green.
NOTE The full version number includes a build number which does not appear on the Firmware
Version/Update window. To retrieve the full number, type http://ip.ip.ip.ip/Version.html in the browser,
where ip.ip.ip.ip denotes the reader IP or host name.
NOTE For more detail on upgrading using an FTP / FTPS server, see Appendix C, FTP Firmware Upgrade.
CAUTION This option is NOT recommended because updating all partitions increases update time and resets all
configurations including user logins. Power disruption during update can cause the reader to fail.