User guide

73
Configuration
Control Panel LCD Displays
1/10/06 170PAX4 User Guide 57516L-002 Rev. A
Set Ribbon Tension
This parameter sets the tension applied to the ribbon supply spindle. The
correct setting is determined by a combination of the ribbon width and the
ribbon length (Table 7).
Default: HIGH
Selections: LOW, MEDIUM, HIGH
To change the value shown:
1. Determine the correct tension setting for the ribbon being used.
2. Press the left or right oval to scroll through the options.
3. Press
SETUP/EXIT to exit setup mode.
4. Select the
PERMANENT save option.
5. Press NEXT.
6. Turn the print engine Off (
O) and back On (I).
Select Media Power-Up Option
This parameter sets the action of the media when you turn on the
print engine.
Default: CALIBRATION
Selections: FEED, CALIBRATION, LENGTH, SHORT CAL, and NO
MOTION
Feed—feeds the labels to the first registration point.
Calibration—determines the length of the label and adjusts the
sensor settings.
Length—In continuous mode, feeds the last stored label length. In
noncontinuous mode, calibrates based on the maximum label length
setting (see Set Maximum Label Length on page 59).
Short Cal—calibrates label length using the current sensor settings.
No Motion—the media does not move. You must press
FEED to
cause the print engine to resynch to the start of the next label.
To change the value shown:
1. Press the left or right oval to scroll through the options.
Table 6 • Print Engine Parameters (Page 19 of 26)
Parameter
Action/Explanation
RIBBON TENSION
- HIGH +
Table 7 • Ribbon Tension Settings
Ribbon
Width
Ribbon Length
300 Meters 450 Meters 600 Meters 900 Meters
3 to 5 in. Low Low Low Low
4 to 6 in. Low Low or
Medium
Low or
Medium
Medium
5 to 7 in. Low or
Medium
Medium Medium
or High
High
MEDIA POWER UP
- CALIBRATION +