User guide

Data Ports
Applicator Interface Connector
57516L-001 Rev. 1 10/12/2004 170PAX4 User Guide 123
5 PAUSE Input To toggle the current pause state, this input must be
asserted LOW for 200 milliseconds, or until the
SERVICE REQUIRED output (pin 10) changes state.
6 REPRINT Input If the Reprint feature is enabled, this input must be
asserted LOW to cause the print engine to reprint the last
label. See Set Reprint Mode on page 73 for more
information.
If the Reprint feature is disabled, this input is ignored.
7+28V
(Fused at 500 mA.
See Figure 55
on page 125 for fuse
location.)
Caution • Replace
the fuse only with
one of the same
type and rating.
Power Interface Power Supply – supplies power to external
sensors as required.
8 POWER GROUND
(+28 V Return)
Ground Interface Power Ground.
9 RIBBON LOW Output Asserted HIGH if the Ribbon Low feature is enabled and
the amount of ribbon remaining on the supply spool is
below a specific threshold level. See Set Ribbon Low
Mode on page 72 for more information.
If the Ribbon Low feature is disabled, this output lead is
disabled.
10 SERVICE
REQUIRED
Output Asserted LOW if the media cover is open, the printhead
is open, the ribbon is out, the media is out, the print
engine is paused, or an operational fault occurs.
If the applicator Resynch mode is set to Error mode, this
signal also asserts LOW for a Resynch error.
11 END PRINT Output MODE 0: The Applicator Port is OFF.
MODE 1: Asserted LOW only while the print engine is
moving the label forward; otherwise de-asserted HIGH.
MODE 2: Asserted HIGH only while the print engine is
moving the label forward; otherwise de-asserted LOW.
MODE 3: (Default) Asserted LOW for 20 milliseconds
when a label has been completed and positioned. Not
asserted during continuous printing.
MODE 4: Asserted HIGH for 20 milliseconds when a
label has been completed and positioned. Not asserted
during continuous printing.
Table 17 • Applicator Interface Connector Pin Configuration (Continued)
Pin No. Signal Name Signal Type Description