User guide

87
Configuration
Control Panel Parameters
6/29/11 110PAX4/R110PAX4 User Guide 57512L-004 Rev. A
These parameters are automatically set during the calibration procedure
and should be changed only by a qualified service technician. Refer to the
ZPL II Programming Guide for information on these parameters.
To skip these parameters:
1. Press NEXT/SAVE repeatedly.
Adjust LCD Display
This parameter allows you to adjust the brightness of your LCD if it is
difficult to read.
Default: 10
Range: 00 to 19
To change the value shown:
1. Press the right oval to increase the value (increase brightness).
2. Press the left oval to decrease the value (reduce brightness).
Select Format Convert
Selects the bitmap scaling factor. The first number is the original dots per
inch (dpi) value; the second, the dpi to which you would like to scale.
Default: NONE
Selections:
NONE, 150 300, 150 600, 200 600, 300 600
To change the value shown:
1. Press the left or right oval to scroll through the options.
Set RTS Take-Up Dancer Arm Calibration Value
This parameter is used as a diagnostic tool to monitor the voltage supplied
to the Ribbon Tensioning System Take-Up Dancer Arm. Refer to the
Maintenance Manual for information.
Table 7 • Print Engine Parameters (Page 24 of 25)
Parameter
Action/Explanation
WEB S. 073
- +
MEDIA S. 075
- +
RIBBON S. 071
- +
MARK S. 000
- +
MARK MED S. 000
- +
MEDIA LED 082
- +
RIBBON LED 008
- +
MARK LED 005
- +
LCD ADJUST +10
- +
FORMAT CONVERT
- NONE +
RTS TAKEUP ARM
XXX