User guide

85
Configuration
Control Panel Parameters
6/29/11 110PAX4/R110PAX4 User Guide 57512L-004 Rev. A
Select Start Print Signal
This parameter determines how the print engine reacts to the Start Print
Signal input on pin 3 of the applicator interface connector at the rear of the
print engine.
Caution • Start Print Signal is set by the applicator manufacturer and
should not be changed unless the factory defaults have been reloaded.
Please make a note of it. While other choices are valid, the print engine
must be returned to its designated setting for it to work properly.
Default: PULSE MODE
Selections: PULSE MODE, LEVEL MODE
PULSE MODE—Labels print when the signal transitions from
HIGH to LOW.
LEVEL MODE—Labels print as long as the signal is asserted LOW.
To change the value shown:
1. Press the left or right oval to toggle between the options.
Select Resynch Mode
This parameter determines how the print engine reacts if the label
synchronization is lost and the label top is not where expected.
Default: FEED MODE
Selections: FEED MODE, ERROR MODE
FEED MODE—If the label top is not where expected, the print engine
feeds a blank label to find the label top position.
ERROR MODE—If the label top is not where expected, the
print engine stops, enters Pause mode, displays the message
Error
Condition Feed Label
, flashes the ERROR light, and asserts the
Service Required signal (pin 10 on the Applicator Interface Connector).
To resynch the media to the top of the label in Error mode, press
PAUSE to exit Pause mode. The ERROR light stops flashing, and the
Service Required signal is deactivated. The action of the print engine is
determined by the
Head Close configuration selection (see Select
Head Close Option on page 82).
To change the value shown:
1. Press the left or right oval to toggle between the options.
Table 7 • Print Engine Parameters (Page 22 of 25)
Parameter
Action/Explanation
START PRINT SIG
- PULSE MODE +
RESYNCH MODE
- FEED MODE +