User guide
143
Data Ports
Applicator Interface Connector
6/29/11 110PAX4/R110PAX4 User Guide 57512L-004 Rev. A
Jumper Configurations and Pinouts for +5 V I/O Operation
Jumpers J4 and J5 are used together to produce isolated or non-isolated modes of operation for
applicator input and output control signals. J4 configures the +5 V source for the optoisolator
circuits, and J5 configures the ground. For proper operation, when J4 is installed, J5 must be
installed, and when J4 is removed, J5 must be removed.
Table 21 describes the pin and jumper configurations for +5 V I/O operation. See Figure 41
on page 145 for jumper locations.
Table 21 • Non-Isolated and Isolated Modes for +5V Operation
Non-Isolated (Jumpers In) Isolated (Jumpers Out)
Pin 1 Ground +5V, Jumper J5 In
I/O ground is connected to the print engine
signal ground.
External Ground +5V, Jumper J5 Out
I/O ground is disconnected from the
print engine signal ground. Ground must be
provided externally to this pin.
Pin 2 +5V Output, Jumper J4 In
+5 V I/O is connected to the applicator
interface circuit +5 V Supply.
External +5V Input, Jumper J4 Out
+5 V I/O is disconnected from the applicator
interface circuit +5 V Supply. The +5 V for the
applicator interface optoisolator circuits must be
provided externally. This input also supplies
voltage for output signal pull-up resistors.
Pinouts
2
3
4
5
6
7
8
9
1
1010
1111
1212
1313
1414
1515
+5V+5V
J4J4
J5J5
1A1A
+5V+5V +5V+5V
+28V+28V
+28V+28V
500 mA500 mA
2
3
4
5
6
7
8
9
1
1010
1111
1212
1313
1414
1515
J4J4
J5J5
+5V+5V
1A1A
+5V+5V
+28V+28V
+28V+28V
+5V+5V
500 mA500 mA