Specifications

32056L Rev. 2 12/4/01 105SL Maintenance Manual Page 3-7
TROUBLESHOOTING SECTION 3
)(('.H\DQG3$86(.H\6HOI7HVW
To reset the printer configuration to the factory default values, press these two keys at the
same time, while turning the power ON. The printer performs a normal startup, resets to
factory defaults, calibrates, and saves the settings.
3$86(.H\DQG&$1&(/.H\6HOI7HVW
This self test can be used to verify proper printer operation after parts have been replaced or
adjusted. When activated, the printer prints a maximum of 500 head test labels. A serialized
number prints on each label. Pressing the PAUSE key suspends printing. Resuming printing
after pausing causes the first label to backfeed prior to printing, and the last label to feed
forward to its rest position. To stop printing, pause the printer and press the CANCEL key, or
place the power switch in the Off (O) position. See Figure 3-5 for a sample label.
)(('.H\DQG&$1&(/.H\6HOI7HVW
This self test is normally performed during the manufacturing process or after a major
overhaul of the mechanical assemblies. This test prints seven sets of pre-programmed label
formats at speeds of 6
and 2 per second. The printer pauses after each set of label formats.
The sequence of label formats is shown in Table 3-1. Refer to Figure 3-7 through 3-13 for
sample labels.
Figure 3-5. PAUSE Key Loopback Test Sample Label
Table 3-1. Format Sequence
FORMAT PRINTING TEST FUNCTION
1 20 at 6 ips Left Ribbon Wrinkle Test
2 20 at 6 ips Right Ribbon Wrinkle Test
3 20 at 6 ips Bar Code Wrinkle Test (Code-39)
4 20 at 2 ips Left Ribbon Wrinkle Test
5 20 at 2 ips Right Ribbon Wrinkle Test
6 20 at 2 ips Bar Code Wrinkle Test (Code-39)
7 10 at 6 ips Usable Area Test
8 10 at 6 ips Head Temperature Test
9 10 at 6 ips Upper Smear Test
10 10 at 6 ips Lower Smear Test
11 10 at 2 ips Usable Area Test
12 10 at 2 ips Head Temperature Test
13 10 at 2 ips Upper Smear Test
14 10 at 2 ips Lower Smear Test