Specifications

Page 2-40 105SL Maintenance Manual 32056L Rev. 2 12/4/01
SECTION 2 OPERATION OVERVIEW
NOTE: On diagnostic printouts:
FE indicates a framing error.
OE indicates an overrun error.
PE indicates parity error.
NE indicates noise.
For any errors, check that your communication parameters are correct. Set the print width
equal to or less than the label width used for the test.
Press the NEXT key to display CONTROL PREFIX.
7KH&RQWURO3UHIL[&KDUDFWHU
The control prefix character is a two-digit hex value. Once configured, this character
signifies the start of a ZPL/ZPL II control instruction.
Press the left oval key to move to the next digit position, and press the right oval key to
increase the value of the digit. (The “H” is displayed but not entered as part of the value.)
Default: 7E (tilde)
Range: 00 – FF (Exclude the values indicated on the ASCII Code Chart in the
ZPL II Guide Volume II Appendix B.)
Press the NEXT key to display FORMAT PREFIX.
7KH)RUPDW3UHIL[&KDUDFWHU
The format prefix character is a two-digit hex value. Once configured, this character signifies
the start of a ZPL or ZPL II format instruction.
Press the left oval key to move to the next digit position, and press the right oval key to
increase the value of the digit. (The “H” is displayed but not entered as part of the value.)
Default: 5E (caret)
Range: 00 – FF (Exclude the values indicated on the ASCII Code Chart in the
ZPL II Guide Volume II Appendix B.)
Press the NEXT key to display DELIMITER CHAR.
&21752/35(),;
!(+ 
)250$735(),;
A!(+