Specifications
32056L Rev. 2 12/4/01 105SL Maintenance Manual Page 2-25
OPERATION OVERVIEW SECTION 2
2. Press the (+) key to start the calibration procedure. The front panel LCD should show:
3. Press the (–) key to cancel the operation, or open the printhead and remove as many
labels as needed to load a section of blank backing material under the media sensor. If
you are unsure of the media sensor location, refer to Figure 2-24 and Figure 2-25.
4. Press the (+) key to continue. The front panel LCD should show:
5. Press the (–) key to cancel the operation.
or
Remove the ribbon (sliding it as far to the right as possible has the same effect as
removing it), and close the printhead.
6. Press the (+) key to continue. The front panel LCD should show:
7. The printer automatically adjusts the base settings as determined by the media and
ribbon sensors according to the specific media and ribbon combination you are using.
The sensor profile adjustment moves the graph up or down to optimize the readings for
your application.
When this part of the calibration process is completed, the front panel LCD shows:
8. Open the printhead and pull the media forward until a label is positioned under the
media sensor.
9. Move the ribbon back to its proper position. To ensure that the ribbon is smooth, rotate
the take-up spindle a couple of turns.
10. Close the printhead.