Specifications
Page 6-26 105SL Maintenance Manual 32056L Rev. 2 12/4/01
SECTION 6 OPTION KITS
7:,1$;&20081,&$7,216,17(5)$&(%2$5'237,21
This kit (part # 48924)includes the parts necessary to install the Twinax Communications
Interface Board option into the 105SL. Use the following procedure to install and set up the
interface board.
1. Refer to RRP No. 1 on page 4-10 and place the power switch in the Off (O) position.
Disconnect the AC power cord.
2. Refer to Figure 6-14. At the rear of the printer, remove the two screws and the blank
cover plate or an existing optional interface board positioned next to the serial and
parallel interface connectors.
3. Refer to RRP No. 2 on page 4-12 and remove the electronics cover.
NOTE: Figure 6-21 illustrates 105SL printers with configuration numbers
10500-0
XXX-XXXX and 10500-1XXX-XXXX. Figure 6-22 illustrates 105SL
printers with configuration numbers 10500-2XXX-XXXX and
10500-3XXX-XXXX.
4. Refer to Figure 6-21 or Figure 6-22. Plug the 40 pin interface cable into the keyed
interface data cable connector on the main logic board. Use connector J4 on printers
with configuration numbers 10500-0XXX-XXXX and 10500-1XXX-XXXX. Use
connector P21 on printers with configuration numbers 10500-2XXX-XXXX and
10500-3XXX-XXXX.
5. Insert the twinax interface board into the mounting slot. Attach the other end of the
interface data cable into the data cable connector at the rear of the twinax interface
board.
Figure 6-21. Twinax Interface Board Installation (Printer Configurations
10500-0XXX-XXXX and 10500-1XXX-XXXX)