Specifications
Page 4-86 105SL Maintenance Manual 32056L Rev. 2 12/4/01
SECTION 4 PREVENTIVE AND CORRECTIVE MAINTENANCE
5. Refer to Figure 4-65. Bunch the printhead power and data cables along with the ribbon
sensor cable. Install a tie wrap around all three cables and the printhead pivot shaft.
Snug it up and cut off the excess.
6. Carefully position the alignment slots in the new printhead over the alignment posts on
the underside of the mounting bracket.
7. Seat the printhead completely and hold it in place. Carefully tighten the mounting screw
to secure it to the mounting plate.
8. Refer to Figure 4-66. Use a cleaning swab from the printhead cleaning kit (Zebra
part # 01429) and thoroughly clean the gray area of the new printhead.
9. Carefully close and open the printhead to ensure that there are no obstructions.
10. Route the ribbon sensor power cable through the two white plastic clamps to the main
logic board. Close and secure the clamps with hex nuts.
11. Plug the ribbon sensor wire connector into the connector on the main logic board.
12. Reinstall the media and ribbon. Close the printhead.
13. Close the media cover.
14. Reinstall the electronics cover.
15. Reconnect the data cables and the power cord.
16. Reconnect the power cable to the power source. Place the power switch in the On (I)
position.
17. Perform Media and Ribbon Calibration procedure.
Figure 4-66. Printhead Cleaning
Ribbon
Sensor
Black
Mark
Sensor
Take-Label
Sensors
Peel-off/Tear-off
Bar
Platen Roller
Printhead
Printhead
Lever