Specifications
Page 4-74 105SL Maintenance Manual 32056L Rev. 2 12/4/01
SECTION 4 PREVENTIVE AND CORRECTIVE MAINTENANCE
11. Install the wave washer, flat washer, spacer and belt pulley. Secure the new spindle
assembly with the E-ring.
12. Reinstall and adjust the tension of the main drive belt.
13. Reinstall the electronics cover.
14. Reinstall the media and ribbon. Close the printhead.
15. Reconnect the power cord.
16. Reconnect the power cord to the power source.
17. Print the CANCEL Key Self Test label and check the ribbon tension.
18. If ribbon tension is not correct, refer to “Spindle Tension Adjustment” on page 4-39 and
check the tension. If ribbon tension is proper, place the power switch in the Off (O)
position and reconnect the data cables.
5HDU3DQHO5HSODFHPHQW
1. Refer to RRP No. 1 on page 4-10 and place the power switch in the Off (O) position
and disconnect the AC power cord. Disconnect the data cables.
2. Refer to RRP No. 2 on page 4-12 and remove the electronics cover.
3. Refer to Figure 4-56. Remove the screw and the option card shield. Press the card
release button to remove any font card or memory card.
4. Remove optional interface board if installed.
Figure 4-55. Ribbon Take-up Spindle
POWER
TAKE LABEL
ERROR
CHECK RIBBON
CANCEL
FEED
PAPE R OU T
PAUSE
DATA
PREVIOUS
NEXT/SAVE
SETUP/EXIT
Pulley
E-Ring
Spacer
Flat Washer
Wave Washer
Allen Screws (3)
Washers (3)
Bearing
Housing
Ribbon Take-up
Spindle