Specifications

32056L Rev. 2 12/4/01 105SL Maintenance Manual Page 4-59
PREVENTIVE AND CORRECTIVE MAINTENANCE SECTION 4
8. Refer to Figure 4-45. Attach the cutter power cable to connector J2 on the new cutter
board.
9. Attach the cutter data cable to connector J1 on the new cutter PCB.
NOTE: The cutter motor leads have a polarized connector.
10. Route the cutter stepper motor wires between the two right hand pems and out under
the bottom of the new cutter PCB. Attach the motor wires to connector J4 on the new
cutter PCB. Make sure the black lead is to the left.
11. Refer to Figure 4-44. Secure the new cutter PCB to the pems with four screws.
12. Refer to Figure 4-45. Plug the cutter optical sensor connector into the cutter optical
connector J3 on the new cutter PCB.
13. Dress all the wires to ensure that during cutting no wiring touches any moving parts.
NOTE: When the Cutter PCB is changed, the lower drive arm alignment must be
checked.
14. Proceed to “Lower Drive Arm Alignment” procedure.
Figure 4-44. Cutter PCB Removal and Installation
Cutter PCB
Ribbon Cable
J4
Cutter Motor
Power Cable
Pems
Allen Screw