Specifications
32056L Rev. 2 12/4/01 105SL Maintenance Manual Page 4-37
PREVENTIVE AND CORRECTIVE MAINTENANCE SECTION 4
7DNH/DEHO/DEHO$YDLODEOH6HQVRU$OLJQPHQW
The take label sensor activates only when the printer is set to peel-off mode. This mode
requires the Rewind or Peel option. The media sensor pair is NOT installed on printers without
this option.
Refer to Figure 4-26 for the location of the take label sensor components. When the beam is
broken, the printer will be inhibited from printing or feeding in peel-off mode only. It may,
however, accept additional label formats if the buffer is not full. There is no sensitivity
adjustment for the take label sensor. If you encounter problems, make certain the printer is set
to peel-off mode and the sensors are aligned. Sensors are aligned at the factory or when the
media rewind spindle option is installed. No adjustments are required after installation.
0HGLD7UDFNLQJ$GMXVWPHQW
5HZLQG0RGH
If the media walks from side to side, tears, or wrinkles against the media rewind tracking plate,
it is necessary to adjust the rewind plate assembly.
Refer to Figure 4-27.
NOTE: Moving the outer end of the hook plate up forces the media toward the
rewind tracking plate; moving this end down moves the media away from
the tracking plate. The opposite effect occurs if the same adjustments are
made on the inner end of the hook plate.
1. Remove the rewind plate assembly and loosen the two hex nuts that attach the hook
plate to the rewind plate.
2. Move the outer end of the hook plate up to force the media toward the rewind tracking
plate (see Figure 4-29), or move the outer end of the hook plate down to force the
media away from the rewind tracking plate.
3. Tighten the hex nuts, and reinstall the rewind plate assembly. Print a number of test
labels. If problems persist, readjust the hook plate.
Figure 4-26. Take Label Sensor Location
Take
Label
Sensors