32056L Rev. 2 12/4/01 105SL Maintenance Manual Page 4-29
PREVENTIVE AND CORRECTIVE MAINTENANCE SECTION 4
10. Refer to Figure 4-18 and connect the printhead data cable and the power cable to the
replacement printhead.
11. Carefully position the alignment slots in the new printhead over the alignment posts on
the underside of the mounting bracket.
12. Seat the printhead completely and hold it in place. Carefully tighten the mounting screw
to secure it to the mounting plate.
13. Refer to Figure 4-20. Use a cleaning swab from the printhead cleaning kit (Zebra
part # 01429) and thoroughly clean the gray area of the new printhead.
14. Carefully close and open the printhead to ensure that there are no obstructions.
15. Reinstall the media and ribbon. Close the printhead.
16. Connect the AC power cord. Place the power switch to the On (I) position.
17. After the AUTO CALIBRATION/POST, press the SETUP/EXIT key to enter the
configuration mode. Press NEXT/SAVE key until you get to the HEAD RESISTOR
prompt. Enter the new printhead resistance value and permanently save the new
configuration.
WARNING:
IF THE DATA CABLE IS NOT CONNECTED SECURELY TO THE
PRINTHEAD, A HEAD COLD WARNING MESSAGE MAY APPEAR ON THE
DISPLAY EVEN THOUGH THE PRINTHEAD MAY BE VERY HOT.
ACCIDENTLY TOUCHING A HOT PRINTHEAD CAN CAUSE SEVERE
BURNS.
Figure 4-20. Printhead Cleaning
Ribbon
Sensor
Black
Mark
Sensor
Take-Label
Sensors
Peel-off/Tear-off
Bar
Platen Roller
Printhead
Printhead
Lever