Datasheet
Installation and Setup
Changing the Printer Driver Options (Properties)
980006-001 Rev. A Zebra P630i & P640i Card Printer Service Manual 65
3. Heater Temperature
This is the set point temperature (i.e., the temperature desired) not the actual temperature.
For actuals, see Sensor Data on page 71.
4. Line Voltage
If Auto is selected, the printer guesses line voltage based on line frequency, assuming that
110V will be @ 60Hz and 230V @ 50Hz. If this is not the case in your locality, the printer
will guess wrong; and you should set the voltage manually.
Note • Temperatures are monitored by thermocouples at the core of the heated rollers.
Surface temperatures may differ significantly.
Caution • Running the printer at 220V, 60Hz in Auto mode may cause premature failure
of the heaters. Running the printer at 110V, 50Hz in Auto mode may cause abnormally
long heat-up time and poor temperature control. Either will result in a heater error
message in the printer status screen.