Datasheet
140 Zebra P110i / P110m / P120i Card Printers Service Manual 980584-001 Rev. A
5.32 Platen Roller
With the Ribbon Take-Up Motor removed, you can remove the Platen Roller.
Step 1. With a Phillips screwdriver, carefully push the Platen Roller shaft out of its right-
side mounting hole.
Step 2. Turn the Print Engine over, reach in, and remove the Platen Roller.