Datasheet
980584-001 Rev. A Zebra P110i / P110m / P120i Card Printers Service Manual 139
Step 3. With a TORX T8 driver, remove the screw holding the motor gear (#2) in place.
Step 4. Remove the gear.
Step 5. With a TORX T10 driver, remove the three “outside” screws holding the motor to
the frame. Note that the orange arrows point out the three mounting screws.
Step 6. Remove the Ribbon Take-Up Motor.
Replacement
Important • When re-installing the gears, ensure that the grooves (outlined in orange) are