User's Manual Part 2
85
Operations
Adjust Media Sensors
2/23/09 Xi4 User Guide P1009874-001
Upper Media Sensor—Outside Half of Media
To adjust the upper media sensor for the outside half of the media, complete
these steps (all models except the 220Xi4):
1. Remove the ribbon (if ribbon is used).
2. Locate the upper media sensor adjustment screw (1). The upper media sensor eye is
directly below the adjustment screw head.
3. Using a thin, flat-blade screwdriver, loosen and then remove the upper media sensor
adjustment screw.
4. Lift the upper media sensor assembly from the slot, and move it and the wire cover to the
outside slot. Carefully pull the wires through the cable tie. You may need to set aside the
sensor wire cover if the adjustment is too far to the outside.
5. Replace and slightly tighten the adjustment screw.
XX
YY
ZZ
1
XX
YY
ZZ