User's Manual Part 2
83
Operations
Adjust Media Sensors
2/23/09 Xi4 User Guide P1009874-001
Adjust Media Sensors
The transmissive sensor consists of two sections: a light source (the lower media sensor) and a
light sensor (the upper media sensor). The media passes between the two.
Adjust these sensors only when the printer cannot detect the top of the label. The control panel
LCD displays
ERROR CONDITION PAPER OUT, even though there are labels loaded in
the printer.
Upper Media Sensor—Inside Half of Media
To adjust the upper media sensor for the inside half of the media, complete
these steps:
1. Remove the ribbon (if ribbon is used).
2. Locate the upper media sensor adjustment screw (1). The upper media sensor eye is
directly below the adjustment screw head.
Note • For most models of Xi4, the upper media sensor can be positioned along the inside
half of the media (the side closest to the back frame of the printer) or the outside half of the
media (the side farthest from the back frame of the printer). However, for the 220Xi4, you
cannot move the sensors to the outside half of the media.
XX
YY
ZZ
1