User's Manual

User Guide
___________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________
55
User Guide, WherePort IV D1300 REV A
© Copyright WhereNet, Corp. 2008 WhereNet Confidential
12.5.3. Phase
Set the phase.
PHS n<cr>
Valid range for n is 0 through 3 where 0 equals 0º, 1-90 º, 2-180 º, and 3-270 º.
Example:
PHS 2<cr>
Sets the phase to 2.
Considerations:
When WherePort IV fields overlap, the phase of each WherePort IV must be set to match to placement of
the ports.
12.5.4. WherePort IV ID
Sets the WherePort IV Id. The valid range is 0 to 32,767.
WID n<cr>
Example:
WID 4<cr>
Sets the WID to 4.
Considerations:
WherePort IV IDs 0 through 255 are used for an alternate blink mode. When a WhereTag is pinged by a
WherePort IV with an ID less than or equal to 255 the tag is converted to the alternate blink mode.
CAUTION: Do not use the alternate blink mode without consulting the WhereNet technical staff.