Figure 39 Adjacent WherePort IV Configuration
10.4. Adjacent WherePort IVs
Adjacent WherePort IVs require that some additional variables be set:
Power Level Select a power lever from 1 to 8. The highest power level is 8. Note that the WP4 power
level has 31 steps with 31 as the max. To convert between this program range to the WP4, multiply the
program power step by 4 and subtract 1 to achieve the WP4 power level.
Tag to WherePort IV Height Set from 0 to 20 feet.
Distance between WherePort IVs (feet) 0 to 50 feet in five foot increments.
Are the WherePort IVs Synchronized Yes or no (Yes, when wired together).
WherePort IV #1 Phase 0, 90, 180, or 270.
WherePort IV #2 Phase 0, 90, 180, or 270.