User's Manual

User Guide
___________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________
45
User Guide, WherePort IV D1300 REV A
© Copyright WhereNet, Corp. 2008 WhereNet Confidential
Figure 205 Sample Graph
The graph shows the guaranteed capture area in green and the uncertainty area in yellow for a single
WherePort IV, mounted horizontally, with a power level of 4, and a tag to WherePort IV height of 4
feet for a tag with orientation 2. The scale is 10.