Power over Ethernet
POE
AC/48VDC
Adapter
Master
Slave 1Slave 2
Sync OutSync In Sync InSync Out
RJ-11 RJ-11
RJ-45
RJ-45
Figure 2 Wiring Schematic for Power and Synchronization
Each 48 VDC Adapter supports one WherePort IV.
5.3. Health Tag
A WhereTag that is programmed to blink when there is no signal from the WherePort IV may be
mounted to each WherePort IV. This optional tag is called a health tag because a signal from this tag
indicates that there is something wrong with the WherePort IV that has caused it to stop signaling.
5.4. WherePort IV Mounting
The WherePort IV is mounted using a bracket (Figure 3). It can be mounted onto a wall or ceiling. For
details on installing the WherePort IV see the Installation Instructions.