User's Manual

User Guide
WherePort III User Guide
©2010 Zebra Enterprise Solutions. WherePort and all product names and numbers are Zebra Enterprise Solutions trademarks.
A
ll other trademarks are the property of their respective owners.
A string of 24 ASCII-HEX characters to set the 96-bit data payload of the WherePort.
7.5.11 EXE
EXE n<cr>
Send message to magnetic field generator and the flash memory.
7.5.12 Sequence Mode
Set number of WherePort in the chain for sequencing mode.
CMW n<cr>
Where n is a value of 1 through 15. A value of 0 disables sequence mode. A value of 1
means that there is a master and 1 slave.
Example
CMW 2<cr>
Sets the number of WherePorts in the chain to 3, one master and 2 slaves.
7.5.13 Sequence Mode Message Number
CMC n<cr>
N is a value from 0 to 15. Sets the number of messages to send for each WherePort in
sequence mode. 0 disables sequencing mode.
The dwell time (how long it takes to send the programmed number of messages)
increases as the number of messages increases. Table 1 lists the dwell times for the
available combinations of message lengths and message numbers. The types are listed in
the left column. The number of messages are listed in the body of the table. The dwell
time is shown in the header column.
Table 1 Dwell Time (in seconds)
Message
Type
0.2 0.5 1.0 2.0 3.0 4.0 5.0 10 15 20
1
25 64 128 255
2
12 30 60 120 181 255
3
8 20 41 82 123 164 205
4
3 7 14 27 41 55 68 137 205 255
5
3 7 14 27 41 55 68 137 205 255
6
3 7 14 27 41 55 68 137 205 255