Example
RSP 1<cr>
Set the response blink type to 72 bits.
7.5.7 Count
Set the WherePort response blink count (44 bit message only).
CNT n<cr>
Valid range for n is 0 through 15.
Example
CNT 4<cr>
Sets the blink count to 4.
7.5.8 Interval
Set the WherePort response blink interval (44 bit message only ) where n is 0 to 7.
INT n<cr>
7.5.9 Trigger
Set the re-trigger response (44 bit message only).
TRG n<cr>
Where n is a value 0 through 15.
Example
TRG 4<cr>
Sets the re-trigger response to .
7.5.10 Data
Set the 96 bit data payload (144 bit message only).
DAT [string]<cr>
String of 24 ASCII-HEX characters; set the 96 bit data payload (144 bit message only).
String of 22 ASCII-HEX characters: set the 96 bit data payload, payload CRC
automatically calculated (144 bit message only).
Example
DAT string<cr>