Example
PHS 2<cr>
Sets the phase to 2.
Considerations
When WherePort fields overlap, the phase of each WherePort must be set to match to
placement of the ports.
7.5.4 WherePort ID
Sets the WherePort Id. The valid range is 0 to 32,767.
WID n<cr>
Example
WID 4<cr>
Sets the WID to 4.
Considerations
WherePort IDs 0 through 255 are used for an alternate blink mode. When a WhereTag is
pinged by a WherePort with an ID less than or equal to 255 the tag is converted to the
alternate blink mode.
CAUTION Do not use the alternate blink mode without consulting the Zebra
Enterprise Solutions technical staff.
7.5.5 Tag Id
Set the tag ID (for 144 bit messages only). The valid range is 0 to 4,294,967,295.
TID n<cr>
Example
TID 4<cr>
Sets the tag id to 4.
Considerations
The tag ID is only set using a 144 bit message.
7.5.6 Response
Sets the tag WherePort response blink type (applies only to 27 bit and 44 bit messages)
RSP n<cr>
1 72 bit
2 144 bit