7.5 Commands
7.5.1 Message Length
Set the length, in bits, of the WherePort message. There are six possible values.
n Value
1
10 bit
2
28 bit
3
44 bit
4
144 bit
5
144 bit with payload CRC1
6
144 bit with payload CRC2
Example
MSG 1<cr>
Sets the message length to 10 bits.
Considerations
Message length affects the dwell time when using sequenced WherePorts.
7.5.2 Power
Set power level, from 0 to 8. When set to 0 the WherePort power is off.
PWR n<cr>
Increasing the power level increases the range.
Example
PWR 8<cr>
Sets the power level to 8.
Considerations
Lower power levels are used to make sure the capture area of the WherePort is restricted
to the zone or area to be monitored.
7.5.3 Phase
Set the phase.
PHS n<cr>
Valid range for n is 0 through 3 where 0 equals 0º, 1-90 º, 2-180 º, and 3-270 º.