User's Manual
___________________________________________________________________________
WhereWand II User’s Guide
___________________________________________________________________________ 49
WhereWand II User’s Guide D1258 rev A
© Copyright WhereNet, Corp. 2002
WhereNet Confidential
not likely, but still may receive the WherePort message. The WherePort field does
reach to the red zone and can cause interference with other WherePorts.
Table 3: WherePort Power vs. Range
Power Green Zone (ft) Yellow Zone (ft) Red Zone (ft)
8 0 - 14 14 - 21 21 - 30
7 0 - 12 12 - 17 17 - 24
6 0 - 8 8 - 11 11 - 17
5 0 - 7 7 - 10 10 - 15
4 0 - 6 6 - 9 9 - 13
3 0 - 5 5 - 8 8 - 11
2 0 - 4 4 - 6 6 - 9
1 0 - 3 3 - 5 5 - 6
5.3.5 Configure WherePort Phase
Selecting <E> from the set WherePort configuration screen allows the user to set
the phase of WherePorts when multiple WherePorts are connected to provide a
larger area of coverage.
The phase of a single WherePort should always be set to 0°.
When multiple WherePorts are connected, the first WherePort in the chain should
always be set to 0°. WherePorts facing the same direction should have the same
phase, and every 90°change in the mounting direction should correspond to a 90°
phase change. Figure 38 shows the WherePort phase setting screen. Figure 39
shows an example of the phase setting in a typical multi-WherePort installation.