5.3.4 Configure WherePort Power
Selecting <D> from the set WherePort configuration screen allows the user to
select from one of eight power levels. The maximum power setting 8 will give
about a 20 foot range. The minimum power setting 1 will give about a 3 foot
range. Care should be taken when setting the power to avoid under covering an
area, or over covering an area and having the signal bleed into undesired areas.
Figure 37 shows the WherePort power screens.
Figure 37: WherePort Power
Table 3 outlines the WherePort to Tag range for the power levels. Since the range
is dependent on the tag orientation in the WherePort field, the table defines 3
zones. The green zone is the range at which the tag will always see the
WherePort, regardless of orientation, as it passes through the zone. The yellow
zone will typically work, but the tag may not receive the WherePort message if it
is oriented poorly in relation to the field. The red zone is an area that the tag will