User's Manual

___________________________________________________________________________
WhereWand II User’s Guide
___________________________________________________________________________ 23
WhereWand II User’s Guide D1258 rev A
© Copyright WhereNet, Corp. 2002
WhereNet Confidential
Table 1: Custom Configuration Parameters
Key Parameter Description
<A> Rate The interval between tag’s normal keep alive blinks.
-> Range is from OFF to 5 seconds to 1 Hour
<B> WP Count The number of blinks the tag transmits in response to receiving a
valid WherePort message.
-> Range is from 0 to 15 blinks
<C> WP Interval The time between each of the WherePort blinks.
-> Range is 5 seconds to 1 minute.
<D> WP Retrigger Set the time after blinking in response to a WherePort that the same
WherePort ID is ignored and will not cause more tag blinks.
-> Range is 1 second to 2 minutes, with 3 different modes.
<E> Sw Count The number of blinks the tag transmits in response to a level change
on one of its switch or telemetry inputs.
-> Range is from 0 to 15 blinks.
<F> Sw Interval The time between each of the switch event blinks
-> Range is 5 seconds to 1 minute.
<G> Sw Retrigger The time after blinking in response to a switch event that the same
event will be ignored and will not cause more tag blinks
->Range is ½ second to 1 minute.
<H> RX Wakeup Select between 200 msec and 500 msec receiver on interval
<I> SB Count Set the number of sub-blinks the tag sends in every blink
-> Range is 1 to 8 sub-blinks.
<J> Long Intrvl Allows the tag to periodically send normal mode blinks with 12
bytes of data appended to the blink
-> Settings are never, every 8
th
or 64
th
blink, or with every blink
More detail on the settings for each parameter is given in the following sections.