User's Manual

93
Configuration
Control Panel Parameters
5/12/08 ZM™ Series/RZ™ Series User Guide 79695L-002 Rev. A
See next column View Sensor Settings
These parameters are automatically set during the calibration procedure
and should be changed only by a qualified service technician. Refer to the
ZPL II Programming Guide for information on these parameters.
To skip these parameters:
1. Press PLUS (+) to skip each of the following parameters:
ZPL and XML only Select Format Convert
Selects the bitmap scaling factor. The first number is the original dots per
inch (dpi) value; the second, the dpi to which you would like to scale.
Default Value: NONE
Selections: NONE, 150o 300, 150 o600, 200 o600, 300 o600
To change the value shown:
1. Press SELECT to select the parameter.
2. Press
PLUS (+) or MINUS (-) to scroll through the options.
3. Press
SELECT to accept any changes and deselect the parameter.
Table 12 • Printer Parameters (Page 24 of 26)
Parameter
Action/Explanation
Configuration
Control Panel Parameters
94
79695L-002 Rev. A ZM™ Series/RZ™ Series User Guide 5/12/08
Select Idle Display
This parameter selects the LCD options for the real-time clock.
Note • If the default value is not selected, pressing PLUS (+) or
MINUS (-) briefly displays the firmware version of the printer.
Default Value: FIRMWARE (FW) VERSION
Selections: MM/DD/YY (24HR), MM/DD/YY (12HR), DD/MM/YY
(24HR), DD/MM/YY (12HR), FW VERSION
To change the value shown:
1. Press SELECT to select the parameter.
2. Press
PLUS (+) or MINUS (-) to scroll through the options.
3. Press
SELECT to accept any changes and deselect the parameter.
Set Real-Time Clock (RTC) Date
This parameter allows you to set the date following the convention selected
in
IDLE DISPLAY
.
To change the value shown:
1. Press SELECT to select the parameter.
2. Press
MINUS (-) to move to the next digit position.
3. Press
PLUS (+) to change the value of the digit.
4. Press
SELECT to accept any changes and deselect the parameter.
Set RTC Time
This parameter allows you to set the time following the convention selected
in
IDLE DISPLAY
.
To change the value shown:
1. Press SELECT to select the parameter.
2. Press the left oval
MINUS (-) to move to the next digit position.
3. Press the right oval
PLUS (+) to change the value of the digit.
4. Press
SELECT to accept any changes and deselect the parameter.
Specify Password Level
This parameter allows you to select whether certain factory-selected menu
items or all menu items are password protected.
Default Value: SELECTED ITEMS
Selections: SELECTED ITEMS, ALL ITEMS
1. Press
SELECT to select the parameter.
2. Press
PLUS (+) or MINUS (-) to toggle between the options.
3. Press
SELECT to accept any changes and deselect the parameter.
Table 12 • Printer Parameters (Page 25 of 26)
Parameter
Action/Explanation