User's Manual
Configuration
Setup Mode
65
79695L-002 Rev. A ZM™ Series/RZ™ Series User Guide 5/12/08
Exit Setup Mode
To leave Setup mode, complete these steps:
1. Press SETUP/EXIT.
The LCD displays
SAVE CHANGES
.
2. Press PLUS (+) or MINUS (-) to display the save options:
3. Press SETUP/EXIT to select the displayed choice.
When the configuration and calibration sequence is done,
PRINTER READY
displays.
LCD Description
PERMANENT
Stores values in the printer even when power is turned off.
TEMPORARY
Saves the changes until power is turned off.
CANCEL
Cancels all changes made since you entered Setup mode,
except for changes made to the darkness and tear-off settings,
which go into effect as soon as they are made.
LOAD DEFAULTS
Restores all parameters other than the network settings back to
the factory defaults. Use care when loading defaults because
you will need to reload all settings that you changed manually.
Note • Loading factory defaults causes the printer to
auto-calibrate.
LOAD LAST SAVE
Loads values from the last permanent save.
DEFAULT NET
Restores the wired and wireless network settings back to
factory defaults.
66
Configuration
Change Password-Protected Parameters
5/12/08 ZM™ Series/RZ™ Series User Guide 79695L-002 Rev. A
Change Password-Protected Parameters
Certain parameters, including the communication parameters, are password-protected by
factory default.
The first time that you attempt to change a password-protected parameter, the printer displays
ENTER PASSWORD
. Before you can change the parameter, you must enter the four-digit
numeric password. After you have entered the password correctly, you do not have to enter it
again unless you leave Setup mode by pressing
SETUP/EXIT or by turning off (O) the printer.
To enter a password for a password-protected parameter, complete
these steps:
1. At the password prompt, use MINUS (-) to change the selected digit position.
2. When you have selected the digit that you wish to change, use PLUS (+) to increase the
selected digit value. Repeat these two steps for each digit of the password.
3. After entering the password, press SELECT.
The parameter you selected to change is displayed. If the password was entered correctly,
you can change the value.
Default Password Value
The default password value is 1234. The password can be changed using the Zebra
Programming Language (ZPL) command
^KP (Define Password) or using the printer’s web
pages (ZebraNet
®
10/100 Print Server, or Wireless Plus Print Server required).
Disable the Password Protection Feature
You can disable the password protection feature so that it no longer prompts you for a
password by setting the password to 0000 via the
^KP ZPL command. To re-enable the
password-protection feature, send the ZPL command
^KPx, where x can be any number from
1 to 9999.
Caution • Do not change password-protected parameters unless you have a complete
understanding of the parameters’ functions. If the parameters are set incorrectly, the printer
may function unpredictably.