User's Guide

___________________________________________________________________________
User Guide
___________________________________________________________________________ 26
TFF-2220-00AA and TFF-2221-00AA User’s Guide D1436 Rev B
©2008 Zebra Enterprise Solutions. WhereCall IV and all product names and numbers are Zebra Enterprise Solutions trademarks. All other trademarks are the property of their respective owners.
4.7.3 Tools
ZES does not provide the required materials and tools for changing batteries with the WhereCall
IV Tags. The following tools will be required to change the WhereCall IV batteries.
One, torque wrench with a 5/64 inch hex drive bit and the torque set to 6.0 + .6 inch-
pounds [0.68 +
0.07 Newton-meters] for the six screws on the bottom cover of the tag.
One, “small, pocket size” flat blade screw driver use to remove batteries from the battery
holder.
One, ESD wrist strap or equivalent static protection device.
4.7.4 Procedure
To change the WhereCall IV batteries, the WhereCall IV must be in OFF mode and display
PWR OFF . See section 4.3 for instructions on turning the WhereCall IV off.
Step 1: Enter battery change mode as follows
Press and hold the button for several seconds until the display starts to cycle between
these options…ISO MODE, CCX MODE, DUALMODE, and CNG BATT. Release the
button when the display shows CNG BATT, then click the button again to activate the
mode. The WhereCall IV is now in a mode that draws more current in bursts to ensure
the circuitry fully discharges when the batteries are removed. This mode will expire in 5
minutes, so the batteries should be replaced within 5 minutes to ensure proper restart of
the internal processors.
Step 2: Remove the 6 screws from the bottom cover of the WhereCall IV and remove the
bottom cover and sealing gasket.