Display
Message Display Meaning
Keep
Alive
Blinks Comments Action required
“S ?” mode
change from
call mode to
switch mode
Indicates that the user can
now change modes if
desired.. To change modes
you must release then press
the button again within 5
seconds. Releasing the
button without pressing it
again will cause firmware
date code to display and the
WhereCall III to enter the
“OFF” mode.
Yes The button must be held for
several seconds during
which the “8888” code will
be momentarily displayed.
Pressing the button again
will generate a “OFF/ON”
response.
Press the button to initiate
“OFF/ON” switch
operation.
(not
blinking)
“OFF” The WhereCall III has been
set to the Off mode. Holding
the button down for more
than five (5) seconds sets the
unit OFF.
No This mode must be used to
ship the WhereCall III and
it may be used during
storage.
Press the button to restore
the unit to operation.
(not
blinking)
Diagnostic check. N/A Display during mode change
operations.
None “8888”
Firmware date code N/A Display during mode change
operation.
None “NNNN”
“ERR1” An “ST1” switch mode
transmission was attempted
but the PA On failed to be
detected.
No This display will persist until
the button is pressed again.
Retry transmission by
pressing the button again.
Call for service if this error
recurs.
“ERR2” An “ST2” switch mode
transmission was attempted
but the PA On failed to be
detected.
No This display will persist until
the button is pressed again.
Retry transmission by
pressing the button again.
Call for service if this error
recurs.
_
____
_
____
“ERR3” The PA On pulse was
detected to be too long. The
tag has lost its configuration.
No This display will persist until
the button is pressed again.
Retry transmission by
pressing the button again.
Call for service if this error
recurs.