User's Manual
Table Of Contents
___________________________________________________________________________
User Guide
___________________________________________________________________________ 11
WhereCall III User Guide D1157 rev A
© Copyright WhereNet, Corp. 2006
WhereNet Confidential
3.2 Mounting WhereCall III with Poly-Lock
Do not apply the poly-lock when the temperature is below 60°F (15°C) or
above 90°F (32°C).
____________
CAUTION
1. Select the desired location in the workstation to mount the WhereCall III.
____________
2. Clean the mounting surface and the back plate of the WhereCall III with
isopropyl alcohol.
3. Select a pair (they are shipped in attached pairs)of Poly-Lock squares, remove
the adhesive backing and press them to the mounting surface, sticky side
down (see Figure 2).
4. Remove the adhesive backing from three additional pairs of Poly-Lock
squares and affix them to the back plate of the WhereCall III to match the
fastener locations on the mounting surface.
5. You should now have four pairs of Poly-Lock attached to the back of the
WhereCall III. Remove the adhesive backing from all four squares.
6. While holding the WhereCall III, aligned with the fasteners on the mounting
surface. Gently press the unit against the mounting surface to assure that the
adhesive on the squares is bonded to the both surfaces.